ZAS0, ZAS1, ZAS2, ZAS3
ZAS0, ZAS1, ZAS2, ZAS3 was recalled on 9 August 2019 under EU Safety Gate alert A12/1214/19. Injuries risk reported by Germany. The bolted connection of the worm gear (6 bolt nuts) is defective.
| Alert Number | A12/1214/19 |
| Brand | Ziehl-Abegg |
| Category | Lifts |
| Risk Type | Injuries |
| Notifying Country | Germany |
| Country of Origin | Unknown |
| Model Number | ZAS0, ZAS1, ZAS2, ZAS3 |
| Published | 9 August 2019 |
Risk Description
The bolted connection of the worm gear (6 bolt nuts) is defective. The worm gear may thus become detached from the drive shaft. That may lead to an uncontrolled movement of the cabin.
Measures Taken
Type of economic operator taking notified measure(s): ManufacturerCategory of measure(s): Technische MaßnahmenDate of entry into force: UnknownType of economic operator taking notified measure(s): ManufacturerCategory of measure(s): Warning consumers of the risksDate of entry into force: 22/03/2019Type of economic operator taking notified measure(s): ManufacturerCategory of measure(s): Warning consumers of the risksDate of entry into force: 19/07/2019
Product Description
Elevator drive with a worm gear
⚠️ What Should You Do?
This recall involves a injuries hazard related to ZAS0, ZAS1, ZAS2, ZAS3.
About this risk
This product has a design or manufacturing defect that can cause physical injuries such as cuts, bruises, fractures, or other bodily harm during normal use.
Recommended action
Stop using the product immediately. Check yourself and family members for any injuries. Store the product safely out of reach and contact the retailer or manufacturer for a replacement or refund.
Who is at risk?
All users, particularly children and elderly people who may be more vulnerable to injury.