Get notified about product recalls

Table lamps - 2 cylindrical table lamps "Present Light"

Electric shock Lighting equipment Serious risk

Table lamps - 2 cylindrical table lamps "Present Light" was reported in a safety alert on 8 February 2008 under EU Safety Gate alert 0134/08. Electric shock risk reported by Germany. The product poses a risk of electric shock because:- the lamp has no cord anchorage and the mains cable conductors are therefore insufficiently protected against tension and twisting; - the mains switch does not have any strain relief;- the cross-section of the mains cable is less than 0.

Check the exact product before acting

Match the brand, model, barcode and product description to the official notice. A shared brand name alone does not establish that your item is affected.

Model: Present Light, GB7000.11-1999 · Barcode: Not specified in this record

Recorded measures: Type of economic operator to whom the measure(s) were ordered: OtherCategory of measure(s): Withdrawal from the market ordered by the authorities.Date of entry into force: Unknown

Read the original Safety Gate record for the affected scope and official instructions. The report date is not confirmation of current stock or an ongoing recall campaign.

General advice below is editorial guidance, separate from the measures recorded by the notifying authority.

Photo of recalled product: Table lamps - 2 cylindrical table lamps "Present Light"
Alert Number0134/08
BrandKitten Dream
CategoryLighting equipment
Risk TypeElectric shock
Notifying CountryGermany
Country of OriginPeople's Republic of China
Model NumberPresent Light, GB7000.11-1999
Published8 February 2008

Risk Description

The product poses a risk of electric shock because:- the lamp has no cord anchorage and the mains cable conductors are therefore insufficiently protected against tension and twisting; - the mains switch does not have any strain relief;- the cross-section of the mains cable is less than 0.5 mm² (the required measurement is 0.75 mm²), which does not provide sufficient mechanical strength; - wires with basic insulation can be touched at the point they enter the lamp housing;- all inscriptions required by the standard, such as the manufacturer's data, the rated voltage,  the Protection Class II-symbol, the type or order number and the rated power of the bulb are missing; - the warnings are not in German.The product does not comply with the Low Voltage Directive and the relevant European standard EN 60598.

Measures Taken

Type of economic operator to whom the measure(s) were ordered: OtherCategory of measure(s): Withdrawal from the market ordered by the authorities.Date of entry into force: Unknown

Product Description

2 identically designed portable table lamps (230V/25W), which differ only by the pattern on the lampshade. • protection class II design, • metal lamp housing, • plastic lampshade, • E14-lamp holder, • mains switch, • approximately 1.1m-long mains cable with moulded europlug, • Dimensions: height: approximately 27.5 cm, Ø approximately 10 cm.

⚡ What Should You Do?

This recall involves a electric shock hazard related to Table lamps - 2 cylindrical table lamps "Present Light".

About this risk

This product has inadequate electrical insulation, faulty wiring, or other electrical defects that can cause electric shock during use.

Recommended action

Unplug the product immediately and do not use it. Do not attempt to repair it yourself. Contact the manufacturer or retailer for a recall remedy.

Who is at risk?

Anyone using the product, especially in wet environments such as bathrooms or kitchens.

View on EU Safety Gate →

Related Recalls