Télémètre à Ultrason à Viser Laser
Télémètre à Ultrason à Viser Laser was reported in a safety alert on 6 December 2013 under EU Safety Gate alert A12/1713/13. Damage to sight risk reported by France. The rangefinder is declared to be a class 2 laser product, but is actually a class 3R laser product and could cause damage to sight.
Check the exact product before acting
Match the brand, model, barcode and product description to the official notice. A shared brand name alone does not establish that your item is affected.
Model: Ref.: 564723 – n°33/2009 · Barcode: Not specified in this record
Recorded measures: Type of economic operator taking notified measure(s): OtherCategory of measure(s): Withdrawal of the product from the marketDate of entry into force: 16/10/2013Type of economic operator taking notified measure(s): OtherCategory of measure(s): Recall of the product from end usersDate of entry into force: 15/10/2013Type of economic operator taking notified measure(s): OtherCategory of measure(s): Destruction of the productDate of entry into force: Unknown
Read the original Safety Gate record for the affected scope and official instructions. The report date is not confirmation of current stock or an ongoing recall campaign.
General advice below is editorial guidance, separate from the measures recorded by the notifying authority.
| Alert Number | A12/1713/13 |
| Brand | MBI |
| Category | Laser pointers |
| Risk Type | Damage to sight |
| Notifying Country | France |
| Country of Origin | People's Republic of China |
| Model Number | Ref.: 564723 – n°33/2009 |
| Published | 6 December 2013 |
Risk Description
The rangefinder is declared to be a class 2 laser product, but is actually a class 3R laser product and could cause damage to sight. The product does not comply with the relevant European standard EN 60825-1 with respect to product information.
Measures Taken
Type of economic operator taking notified measure(s): OtherCategory of measure(s): Withdrawal of the product from the marketDate of entry into force: 16/10/2013Type of economic operator taking notified measure(s): OtherCategory of measure(s): Recall of the product from end usersDate of entry into force: 15/10/2013Type of economic operator taking notified measure(s): OtherCategory of measure(s): Destruction of the productDate of entry into force: Unknown
Product Description
Ultrasonic laser rangefinder.
👁️ What Should You Do?
This recall involves a damage to sight hazard related to Télémètre à Ultrason à Viser Laser.
About this risk
This product can cause eye damage due to excessive light emission (e.g., lasers), projectiles, or chemical splash risk.
Recommended action
Stop using the product immediately. If you have experienced eye discomfort, consult an ophthalmologist. Keep the product away from children.
Who is at risk?
All users, especially children who may look directly at bright light sources.