SANBANG-9052A
SANBANG-9052A was recalled on 4 March 2022 under EU Safety Gate alert A12/00364/22. Health risk / other risk reported by Czechia. The particle/filter retention of the material (measured values: as low as 68%) and the total filtration capacity of the mask (measured mean values: as low as 88%) are insufficient.
| Alert Number | A12/00364/22 |
| Brand | SANBANG |
| Category | Protective equipment |
| Risk Type | Health risk / other |
| Notifying Country | Czechia |
| Country of Origin | People's Republic of China |
| Model Number | 9052A |
| Published | 4 March 2022 |
Risk Description
The particle/filter retention of the material (measured values: as low as 68%) and the total filtration capacity of the mask (measured mean values: as low as 88%) are insufficient. Consequently, the product does not fulfil the health and safety requirements; thus, even if combined with other recommended measures, it may not properly protect. The product does not comply with the Personal Protective Equipment Regulation.
Measures Taken
Type of economic operator to whom the measure(s) were ordered: ImporterCategory of measure(s): Withdrawal of the product from the marketDate of entry into force: 26/01/2022
Product Description
White particle filter half-mask, marked with KN95. Product sold online.
🏥 What Should You Do?
This recall involves a health risk / other hazard related to SANBANG-9052A.
About this risk
This product poses a health risk that does not fall neatly into a single category. It may involve multiple hazards or an unusual safety concern identified by authorities.
Recommended action
Stop using the product and follow any specific instructions from the recall notice. Contact the manufacturer or your national consumer protection authority for more details.
Who is at risk?
All consumers who have purchased this product.