Get notified about product recalls

Recessed luminaire

Electric shock Lighting equipment Serious risk

Recessed luminaire was recalled on 21 March 2008 under EU Safety Gate alert 0340/08. Electric shock risk reported by Hungary. The product poses risk of electric shock because:- the basic-insulated parts (terminal block and single insulated wires) are accessible, - it lacks device protecting against pulling and twisting force,- plastic bushings are missing at the entry hole which has sharp metal edges,- the PVC insulated internal wiring overheats at the measured value of 107°C.

Photo of recalled product: Recessed luminaire
Alert Number0340/08
BrandBRILUX
CategoryLighting equipment
Risk TypeElectric shock
Notifying CountryHungary
Country of OriginPeople's Republic of China
Model NumberR-6000. Bar code: 5 905148 662316
Published21 March 2008

Risk Description

The product poses risk of electric shock because:- the basic-insulated parts (terminal block and single insulated wires) are accessible, - it lacks device protecting against pulling and twisting force,- plastic bushings are missing at the entry hole which has sharp metal edges,- the PVC insulated internal wiring overheats at the measured value of 107°C.The product does not comply with the Low Voltage Directive and the relevant European standard EN 60598.

Measures Taken

Type of economic operator to whom the measure(s) were ordered: OtherCategory of measure(s): Withdrawal from the market and recall from consumers ordered by the authoritiesDate of entry into force: Unknown

Product Description

The metal-covered luminaire provided with aluminium mirror consists of a metal frame and a fitting unit fixed to the frame with riveting. The fitting unit includes the E27 ceramic lampholder and a terminal block. Main components: lampholder ("250V 660W), terminal block ("380V 10A" + mark of approval), internal wiring ("GB5023.3-1997 227IEC 02(RV) 300/500V"). Technical specifications: 230 V; 50 Hz; max 60 W E27; Class I; F-mark, IP20.

⚡ What Should You Do?

This recall involves a electric shock hazard related to Recessed luminaire.

About this risk

This product has inadequate electrical insulation, faulty wiring, or other electrical defects that can cause electric shock during use.

Recommended action

Unplug the product immediately and do not use it. Do not attempt to repair it yourself. Contact the manufacturer or retailer for a recall remedy.

Who is at risk?

Anyone using the product, especially in wet environments such as bathrooms or kitchens.