Power supply units was reported in a safety alert on 23 March 2007 under EU Safety Gate alert 0271/07. Electric shock risk reported by Finland. This product poses a risk of electric shock because - there is not sufficient electrical insulation between the primary circuit connected to the mains and the secondary circuit that can be touched.
Check the exact product before acting
Match the brand, model, barcode and product description to the official notice. A shared brand name alone does not establish that your item is affected.
Model: LC-D500EXP · Barcode: Not specified in this record
Recorded measures: Type of economic operator to whom the measure(s) were ordered: OtherCategory of measure(s): Recall from consumers ordered by the authoritiesDate of entry into force: Unknown
Read the original Safety Gate record for the affected scope and official instructions. The report date is not confirmation of current stock or an ongoing recall campaign.
General advice below is editorial guidance, separate from the measures recorded by the notifying authority.
| Alert Number | 0271/07 |
| Brand | Prescott |
| Category | Electrical appliances and equipment |
| Risk Type | Electric shock |
| Notifying Country | Finland |
| Country of Origin | Unknown |
| Model Number | LC-D500EXP |
| Published | 23 March 2007 |
Risk Description
This product poses a risk of electric shock because - there is not sufficient electrical insulation between the primary circuit connected to the mains and the secondary circuit that can be touched. The secondary circuit can be touched via the product connected to the output of the power supply unit. In particular:- clearances/creepage distances in transformer T2 between the primary and the secondary windings are less than 4 mm/5 mm; a minimum of 0.2 mm between the primary winding and the output wires of the secondary winding and 0.5mm between the secondary winding and the output wires of the primary winding are measured; on the output wires there are not insulation tubes;- clearances/creepage distances in transformer T3 between the primary and the secondary windings are less than 4 mm/5 mm; a minimum of 0.3 mm between the primary winding and the output wires of the secondary winding and 0.3 mm between the secondary winding and the output wires of the primary winding are measured; on the output wires there are not insulation tubes.This product does not comply with the Low Voltage Directive and the relevant European standard EN 60950.
Measures Taken
Type of economic operator to whom the measure(s) were ordered: OtherCategory of measure(s): Recall from consumers ordered by the authoritiesDate of entry into force: Unknown
⚡ What Should You Do?
This recall involves a electric shock hazard related to Power supply units.