Lighting chain, 40 bulbs was recalled on 19 January 2007 under EU Safety Gate alert 0050/07. Fire risk reported by Spain. This product poses a risk of overheating due to the following non-compliances with the relevant European standard EN 60598:- the dimensions of the wire in the chain are less than what is specified in the standard; - the nominal cross-section area of the conductors is 0,18 mm², which is less than the required 0,50 mm²;- the chain is not market with the required warnings ("Do not remove or insert lamps while the lighting chain is connected to the supply.

Photo of recalled product: Lighting chain, 40 bulbs
Alert Number0050/07
BrandVidal
CategoryLighting equipment
Risk TypeFire
Notifying CountrySpain
Country of OriginUnknown
Model NumberRef: 0217141, bar code: 8432583171419
Published19 January 2007

Risk Description

This product poses a risk of overheating due to the following non-compliances with the relevant European standard EN 60598:- the dimensions of the wire in the chain are less than what is specified in the standard; - the nominal cross-section area of the conductors is 0,18 mm², which is less than the required 0,50 mm²;- the chain is not market with the required warnings ("Do not remove or insert lamps while the lighting chain is connected to the supply."; "For series-connected lamps, replace failed lamps immediately by lamps of the same rated voltage and wattage to prevent overheating."; "Ensure all lamp-holders are fitted with a lamp.");- it is not indicated in the product that only replacement lamps of the same type as those supplied with this lighting chain must be used.The product does not comply with the Low Voltage Directive.

Measures Taken

Type of economic operator to whom the measure(s) were ordered: OtherCategory of measure(s): Withdrawal from the market ordered by the authorityDate of entry into force: Unknown

🔥 What Should You Do?

This recall involves a fire hazard related to Lighting chain, 40 bulbs.

About this risk

This product poses a fire risk due to overheating, faulty components, or flammable materials that do not meet safety standards.