Get notified about product recalls

Fluorescent light

Fire Lighting equipment Serious risk

Fluorescent light was recalled on 5 October 2007 under EU Safety Gate alert 0995/07. Fire risk reported by Slovakia. This product poses a serious risk of fire because:- after testing with pellet at temperature 125 ºC, deformation of die-casting occurred,- pellet impress diameter is 7,3 mm (pellet impress diameter is not allowed to be more than 2 mm),- after testing with acicular flame, the material of product ignited,- after testing with burning loop at temperature 850 ºC, the material immediately set on fire without any change of fire to get extinguished spontaneously.

Photo of recalled product: Fluorescent light
Alert Number0995/07
BrandGLOBO
CategoryLighting equipment
Risk TypeFire
Notifying CountrySlovakia
Country of OriginPeople's Republic of China
Model NumberArt. 4235 EE (on typal label)
Published5 October 2007

Risk Description

This product poses a serious risk of fire because:- after testing with pellet at temperature 125 ºC, deformation of die-casting occurred,- pellet impress diameter is 7,3 mm (pellet impress diameter is not allowed to be more than 2 mm),- after testing with acicular flame, the material of product ignited,- after testing with burning loop at temperature 850 ºC, the material immediately set on fire without any change of fire to get extinguished spontaneously. The material kept on burning after loop has been pushed aside. The material also failed after testing at temperature 750 ºC. The product does not comply with the Low Voltage Directive and the relevant European standard EN 60598.

Measures Taken

Type of economic operator taking notified measure(s): OtherCategory of measure(s): Voluntary withdrawal from the market and recall from consumers by the distributor.Date of entry into force: Unknown

Product Description

The product was sold in cardboard box on which there was: "Electronic Wandlampe GLOBO T5 21W and CE mark". The product was labeled by typal label on which there was: "GLOBO Art. 4235EE, max. 21W, T5, 230V, 20/04 and CE mark". Directly on the light there are 2 plugs without marking.

🔥 What Should You Do?

This recall involves a fire hazard related to Fluorescent light.

About this risk

This product poses a fire risk due to overheating, faulty components, or flammable materials that do not meet safety standards.

Recommended action

Disconnect the product from any power source and stop using it immediately. Do not leave it unattended. Store it away from flammable materials. Contact the retailer for a refund.

Who is at risk?

All household members. Fire risks are especially dangerous for sleeping areas and children's rooms.

View on EU Safety Gate →