Cord extension set - Puutarhapistorasia AV-2005

Electric shock Electrical appliances and equipment Serious risk

Cord extension set - Puutarhapistorasia AV-2005 was recalled on 12 September 2008 under EU Safety Gate alert 0992/08. Electric shock risk reported by Finland. The product poses a risk of electric shock because :- during various tests the cable showed cracks both at the sheath and in the insulation resulting in the wires of the conductors becoming accessible;- the temperature of the terminals rose in excess of 100 K in circuits L-earth, when it should not exceed 45 K;- The measured contact pressure of the earthing contacts is 0-4.

Photo of recalled product: Cord extension set - Puutarhapistorasia AV-2005
Alert Number0992/08
BrandMY
CategoryElectrical appliances and equipment
Risk TypeElectric shock
Notifying CountryFinland
Country of OriginPeople's Republic of China
Model NumberType: SGS-202G EAN: 6 417846 032470
Published12 September 2008

Risk Description

The product poses a risk of electric shock because :- during various tests the cable showed cracks both at the sheath and in the insulation resulting in the wires of the conductors becoming accessible;- the temperature of the terminals rose in excess of 100 K in circuits L-earth, when it should not exceed 45 K;- The measured contact pressure of the earthing contacts is 0-4.9 N, when it shall not be less than 5 N;- the measured distance between the side-earthing contacts is 30.3 mm and 30.4 mm, which exceeds the requirement of 29 mm +0/-1 mm.The product does not comply with the Low Voltage Directive and with the relevant European standard EN 60811.

Measures Taken

Type of economic operator to whom the measure(s) were ordered: OtherCategory of measure(s): Withdrawal from the market and recall from consumers ordered by the authorities.Date of entry into force: Unknown

Product Description

Cord extension set with two socket-outlets and a rubber cable of length 1.5 m.

⚡ What Should You Do?

This recall involves a electric shock hazard related to Cord extension set - Puutarhapistorasia AV-2005 .

About this risk

This product has inadequate electrical insulation, faulty wiring, or other electrical defects that can cause electric shock during use.

Recommended action

Unplug the product immediately and do not use it. Do not attempt to repair it yourself. Contact the manufacturer or retailer for a recall remedy.

Who is at risk?

Anyone using the product, especially in wet environments such as bathrooms or kitchens.

View on EU Safety Gate →