CO sensor
CO sensor was reported in a safety alert on 6 December 2019 under EU Safety Gate alert A12/1912/19. Asphyxiation risk reported by Belgium. The CO detector does not give an alarm promptly enough when exposed to low concentrations of CO.
Check the exact product before acting
Match the brand, model, barcode and product description to the official notice. A shared brand name alone does not establish that your item is affected.
Model: FGCD-001 ZW5 V3 2 · Barcode: Not specified in this record
Recorded measures: Type of economic operator taking notified measure(s): ManufacturerCategory of measure(s): Recall of the product from end usersDate of entry into force: 04/09/2019Type of economic operator taking notified measure(s): ManufacturerCategory of measure(s): Making the marketing of the product subject to prior conditionsDate of entry into force: 04/09/2019
Read the original Safety Gate record for the affected scope and official instructions. The report date is not confirmation of current stock or an ongoing recall campaign.
General advice below is editorial guidance, separate from the measures recorded by the notifying authority.
| Alert Number | A12/1912/19 |
| Brand | Fibaro |
| Category | Construction products |
| Risk Type | Asphyxiation |
| Notifying Country | Belgium |
| Country of Origin | Poland |
| Model Number | FGCD-001 ZW5 V3 2 |
| Published | 6 December 2019 |
Risk Description
The CO detector does not give an alarm promptly enough when exposed to low concentrations of CO. A person could be inadvertently exposed to CO for an excessive amount of time, increasing the risk of poisoning and asphyxiation.The product does not comply with the European Standard EN50291.
Measures Taken
Type of economic operator taking notified measure(s): ManufacturerCategory of measure(s): Recall of the product from end usersDate of entry into force: 04/09/2019Type of economic operator taking notified measure(s): ManufacturerCategory of measure(s): Making the marketing of the product subject to prior conditionsDate of entry into force: 04/09/2019
Product Description
Carbon monoxide detector packaged in a white cardboard box with its picture on it.
🛑 What Should You Do?
This recall involves a asphyxiation hazard related to CO sensor.
About this risk
This product can block the airways or restrict breathing, posing a risk of asphyxiation.
Recommended action
Remove the product from the environment immediately, especially from sleeping areas. If someone is having difficulty breathing, call emergency services immediately.
Who is at risk?
Infants and young children are at the highest risk.