ZAS0, ZAS1, ZAS2, ZAS3

Injuries Lifts Serious risk
Photo of recalled product: ZAS0, ZAS1, ZAS2, ZAS3
Alert NumberA12/1214/19
BrandZiehl-Abegg
CategoryLifts
Risk TypeInjuries
Notifying CountryGermany
Country of OriginUnknown
Model NumberZAS0, ZAS1, ZAS2, ZAS3
Published9 August 2019

Risk Description

The bolted connection of the worm gear (6 bolt nuts) is defective. The worm gear may thus become detached from the drive shaft. That may lead to an uncontrolled movement of the cabin.

Measures Taken

Type of economic operator taking notified measure(s): ManufacturerCategory of measure(s): Technische MaßnahmenDate of entry into force: UnknownType of economic operator taking notified measure(s): ManufacturerCategory of measure(s): Warning consumers of the risksDate of entry into force: 22/03/2019Type of economic operator taking notified measure(s): ManufacturerCategory of measure(s): Warning consumers of the risksDate of entry into force: 19/07/2019

Product Description

Elevator drive with a worm gear

View on EU Safety Gate →