TGX: 86X, 87X

Fire, Injuries Motor vehicles Serious risk
Alert NumberA12/1516/17
BrandMan
CategoryMotor vehicles
Risk TypeFire, Injuries
Notifying CountryGermany
Country of OriginGermany
Model NumberType approval number: e4*2007/46*0233* Type: L.2007.46.005
Published10 November 2017

Risk Description

null In the area of the exhaust gas turbo charger, the hydraulic piping installed for the cab tilting equipment is too short, and situated too close to the exhaust gas turbo charger. The pipes could therefore be damaged by heat and/or start to leak. A damaged pipe may cause a tilted cab to tilt back inadvertently. Furthermore, a leaking pipe can result in oil from the hydraulic system of the cab leaking and catching fire upon contact with the hot parts of the exhaust gas turbo charger.

Measures Taken

Type of economic operator taking notified measure(s): ManufacturerCategory of measure(s): Recall of the product from end usersDate of entry into force: Unknown

Product Description

Lorry

View on EU Safety Gate →