QUARTZ SIL540Q
| Alert Number | A11/00109/22 |
| Brand | Quartz (Counterfeit) |
| Category | Pressure equipment/vessels |
| Risk Type | Injuries |
| Notifying Country | France |
| Country of Origin | People's Republic of China |
| Model Number | OD 245, Quartz SIL540Q |
| Published | 30 September 2022 |
Risk Description
The product has a valve which does not correspond to the safety requirements, the materials are too thin to withstand pressure, the pressure container supports (wheels, standing support) are not correctly welded and the purging device has been installed in a place were it may not perform adequately. Furthermore, the pressure indicator device has no warning signs for excessive pressure. Finally, the simple pressure container constituting the air compressor is a falsified product, and bears a CE marking without having undergone the conformity assessment by a relevant competent European conformity assessment body. Consequently, the product may explode, injuring the users. The product does not comply with the requirements of the Simple Pressure Vessels Directive nor with the European standard EN 286-1.
Measures Taken
Type of economic operator to whom the measure(s) were ordered: OtherCategory of measure(s): Recall of the product from end usersDate of entry into force: 20/02/2020Type of economic operator to whom the measure(s) were ordered: OtherCategory of measure(s): Ban on the marketing of the product and any accompanying measuresDate of entry into force: 20/02/2020Type of economic operator taking notified measure(s): DistributorCategory of measure(s): Recall of the product from end usersDate of entry into force: 20/02/2020Type of economic operator taking notified measure(s): ImporterCategory of measure(s): Withdrawal of the product from the marketDate of entry into force: 20/02/2020
Product Description
Simple pressure vessel PS = 8 bar — PT = 12 bar V = 24 L TS = 0/+ 100 °C Product sold online.