Power Supply for InvoSpar JC-668 Neck Massager
Fire Electrical appliances and equipment Serious risk
| Alert Number | SR/00876/25 |
| Brand | Invospar |
| Category | Electrical appliances and equipment |
| Risk Type | Fire |
| Notifying Country | United Kingdom in respect of Northern Ireland |
| Country of Origin | People's Republic of China |
| Model Number | TD12200 |
| Published | 7 March 2025 |
Risk Description
The power supply has poor quality connections to its input and output, with wires soldered directly to the power circuit board with no secondary fixing. Moreover, the input has no fuse to protect the product from overcurrent related faults. This could cause the product to short circuit, presenting a risk of fire. The product does not comply with the requirements of the Low Voltage Directive
Measures Taken
Type of economic operator taking notified measure(s): ManufacturerCategory of measure(s): Recall of the product from end usersDate of entry into force: 17/01/2025
Product Description
Power supply. The product was sold with the InvoSpar JC-668 neck massager between 2017 and 2022 Product sold online, in particular via AMazon.