Particle filter mask
| Alert Number | A12/00328/21 |
| Brand | Brüder Mannesmann |
| Category | Protective equipment |
| Risk Type | Health risk / other |
| Notifying Country | Germany |
| Country of Origin | Germany |
| Model Number | M40210 |
| Published | 12 March 2021 |
Risk Description
The particle/filter retention of the material is insufficient (measured value as low as 83%). Consequently, an excessive amount of particles or microorganisms might pass through the mask, increasing the risk of infection if not combined with additional protective measures. As a result of the labelling, the mask may be worn in areas where hazardous substances are in use or during activities involving asbestos; since the mask fails to offer sufficient protection, this could lead to asbestosis with fatal consequences. The product does not comply with the Personal Protective Equipment Regulation and with the relevant European standard EN 149.
Measures Taken
Type of economic operator taking notified measure(s): RetailerCategory of measure(s): Stop of salesDate of entry into force: Unknown
Product Description
Masks labelled as KN95 and FFP2, 10 masks per pack