KN95 mask
| Alert Number | A12/00779/21 |
| Category | Protective equipment |
| Risk Type | Health risk / other |
| Notifying Country | Iceland |
| Country of Origin | Unknown |
| Published | 4 June 2021 |
Risk Description
The particle/filter retention of the material is insufficient (measured values: as low as 73%) and the total filtration capacity of the mask is insufficient (measured mean values: as low as 60%). Furthermore, the mask does not fit correctly to the face of the user. Consequently, an excessive amount of particles or microorganisms might pass through the mask; thus, even if combined with other recommended measures, it may not properly protect. The product does not comply with the Personal Protective Equipment Regulation and with the relevant European standard EN 149.
Measures Taken
Type of economic operator taking notified measure(s): DistributorCategory of measure(s): Recall of the product from end usersDate of entry into force: 23/03/2021
Product Description
White respiratory protective half-face mask.