DIGITAL POWER STATION BSG 600MAX, DIGITAL POWER STATION BSG 1200MAX

Burns, Fire Electrical appliances and equipment Serious risk
Photo of recalled product: DIGITAL POWER STATION BSG 600MAX, DIGITAL POWER STATION BSG 1200MAX
Alert NumberA12/02198/23
BrandScheppach
CategoryElectrical appliances and equipment
Risk TypeBurns, Fire
Notifying CountryGermany
Country of OriginPeople's Republic of China
Model NumberBLBSG 300, BSG 1200MAX, BSG 500, BSG 600MAX, BSG300
Published15 September 2023

Risk Description

The battery cells of the power station are faulty and they are connected in parallel without temperature protection features. This can cause the battery to overheat and/or cause burns and/or a fire. The product does not comply with the requirements of the Low Voltage Directive nor with the European Standards EN 62040-1, EN 62100-6 and EN 60133-2.

Measures Taken

Type of economic operator taking notified measure(s): ManufacturerCategory of measure(s): Warning consumers of the risksDate of entry into force: UnknownType of economic operator taking notified measure(s): ManufacturerCategory of measure(s): Recall of the product from end usersDate of entry into force: UnknownType of economic operator taking notified measure(s): ManufacturerCategory of measure(s): Withdrawal of the product from the marketDate of entry into force: Unknown

Product Description

BLBSG300 Art.5812801901 Serial n.0162-00000; BJ:01/2022;BSG1200MAX Art.5912804901 n.0162-00000; BJ:01/2022;BSG600MAX Art.5912803901 n.0162-00000; BJ:01/2022;BSG500 Art.5912802901 n.0162-00000; BJ:01/2022; BSG300 Scheppach rt.5912801901,5912801917 n.0162-00000 BJ:01/2022;