Carbon Monoxide Detector
| Alert Number | A12/1750/16 |
| Brand | König |
| Category | Construction products |
| Risk Type | Asphyxiation |
| Notifying Country | The Netherlands |
| Country of Origin | People's Republic of China |
| Model Number | SAS-CA200 |
| Published | 23 December 2016 |
Risk Description
null In case of a defect in the sensor, or in case the sensor is short-circuited or disconnected, the CO detector does not produce a fault signal. Also, if the detector is exposed to high humidity it does not work correctly.The product does not comply with the relevant European standard EN 50291.
Measures Taken
Type of economic operator to whom the measure(s) were ordered: OtherCategory of measure(s): Withdrawal of the product from the marketDate of entry into force: 26/10/2016Type of economic operator to whom the measure(s) were ordered: OtherCategory of measure(s): Ban on the marketing of the product and any accompanying measuresDate of entry into force: 26/10/2016Type of economic operator to whom the measure(s) were ordered: OtherCategory of measure(s): Recall of the product from end usersDate of entry into force: 26/10/2016
Product Description
White CO detector packed in a cardboard box.