Carabiner

Injuries Protective equipment Serious risk
Photo of recalled product: Carabiner
Alert Number0477/08
BrandKONG
CategoryProtective equipment
Risk TypeInjuries
Notifying CountrySpain
Country of OriginItaly
Model NumberKN<>22◊8∞ 7 Batch code : 050588 05
Published2 May 2008

Risk Description

The product poses a risk of injuries because it does not withstand the static strength test which could lead to falls. The test was carried out on the major axis, and it was noted that the connectors break when the following forces are applied:- force of the major axis with the gate pen: 6.1 KN (required level: 7 KN)- force of the major axis with the gate closed: 18.6 KN (required level: 22 KN).

Measures Taken

Type of economic operator to whom the measure(s) were ordered: OtherCategory of measure(s): Withdrawal from the market ordered by the authorities.Date of entry into force: Unknown

Product Description

Oval carabiner. The packaging is a plastic bag attached to card on which the details of the manufacturer are printed.

View on EU Safety Gate →